Learn More
Thermo Scientific™ GeneJET™ Maxiprep-kit voor plasmide
The Thermo Scientific GeneJET Plasmid Maxiprep Kit utilizes silica-based membrane technology in the form of convenient spin column.
Merk: Thermo Scientific™ K0861
Inclusief: Resuspension Solution, Lysis Solution, Neutralization Solution, Endotoxin Binding Reagent, Wash Solution I (concentrated), Wash Solution II (concentrated), RNase A Solution, Elution Buffer (10mM Tris-HCl, pH 8.5), GeneJET Maxi Purification Columns pre-assembled with collection tubes (50mL) and Collection tubes (50mL).
Beschrijving
Thermo Scientific GeneJET Endo-Free Plasmid Maxiprep Kit is a fast, convenient, and efficient system for the large scale purification of endotoxin-free plasmid DNA. Endotoxins are major contaminants found in plasmid DNA preparations. For transfection of sensitive cell lines endotoxins are a major problem. The same applies to in vivo transfection as endotoxins can elicit strong immune responses. Thermo Scientific GeneJET Endo-Free Plasmid Maxiprep Kit is designed to reduce endotoxin level to <0.1 EU/μg of plasmid DNA. The kit utilizes a silica-based membrane technology in the form of convenient spin columns.
Each preparation recovers up to 1000 μg of high copy plasmid DNA from 350 mL of recombinant E. coli cultures that can be used in a wide variety of molecular biology procedures such as transfection of sensitive cells (e.g. Huh-7), in vivo transfection, transformation, restriction endonuclease digestion, automated sequencing, and in vitro transcription.
Highlights
- Pure—free of endotoxins plasmid DNA suitable for transfection of sensitive cells
- Efficient—plasmid recovery resulting in high DNA yields
- Fast—isolation of high quality plasmid DNA in less than 60 minutes
- Convenient—spin column format, centrifuge or vacuum protocol
Applications
Isolated plasmid DNA is suitable for all conventional molecular biology procedures, including:
- Transfection of sensitive cell lines
- FastDigest restriction enzyme digestion
- In vivo transfection
- Automated fluorescent sequencing
- PCR
- Cloning
- Transformation
- In vitro transcription
Includes
- Resuspension Solution
- Lysis Solution
- Neutralization Solution
- Endotoxin Binding Reagent
- Wash Solution I (concentrated)
- Wash Solution II (concentrated)
- RNase A Solution
- Elution Buffer (10 mM Tris-HCl, pH 8.5)
- GeneJET Endo-Free Maxi Purification Columns & Collection Tubes (50 mL, blue-capped)
- GeneJET Endo-Free Maxi Filtration Columns & Collection Tubes (50 mL, white-capped)
Hazardous: No
Quality Control:
- The GeneJET Plasmid Maxiprep Kit is qualified by isolating high copy number plasmid DNA from 250 mL of overnight E. coli culture (OD600 = 2) grown in LB medium following the protocol outlined in the manual.
- The kit passes QC requirements if the purified plasmid DNA has an A260/280 ratio between 1.8 and 1.9 and a dominant band of supercoiled plasmid DNA is observed after agarose gel electrophoresis.
- The functional quality of the plasmid DNA is evaluated by digestion with restriction endonucleases.
Informatie over bestelling
Orders placed Monday through Wednesday ship next day; Thursday and Friday orders ship the following Monday.

Specificatie
400 ng/μL | |
Spin Column | |
Maxi | |
Real-Time Quantitative PCR (qPCR), Transfection, Cloning, Sequencing, In Vitro Transcription, Transformation, Nucleic Acid Labeling, PCR | |
10 Preps | |
GeneJET | |
10 Preps | |
60 min. |
Spin Column | |
Silica Column | |
Bacteria | |
Not High-throughput Compatible (Manual) | |
> 200 μg (Large-Scale) Plasmid DNA | |
Endo-Free Plasmid MaxiPrep Kit | |
Plasmid DNA |
Veiligheid en behandeling
- GeneJET Endo-Free Plasmid Maxiprep Kit
Signaalwoord
- Waarschuwing
Gevarencategorie
- Acute toxiciteit Categorie 4
- Ernstig oogletsel/oogirritatie Categorie 2
- Huidcorrosie/-irritatie Indeling Categorie 2
Gevarenaanduiding
- H302-Schadelijk bij inslikken.
- H315-Veroorzaakt huidirritatie.
- H319-Veroorzaakt ernstige oogirritatie.
Veiligheidsmaatregel
- P264-Na het werken met dit product grondig wassen.
- P270-Niet eten, drinken of roken tijdens het gebruik van dit product.
- P280-Beschermende handschoenen/beschermende kleding/oogbescherming/gelaatsbescherming dragen.
- P301+P310-NA INSLIKKEN: onmiddellijk een ANTIGIFCENTRUM/arts/ raadplegen.
- P302+P352-BIJ CONTACT MET DE HUID: met veel water/ wassen.
- P305+P351+P338-BIJ CONTACT MET DE OGEN: voorzichtig afspoelen met water gedurende een aantal minuten; contactlenzen verwijderen, indien mogelijk; blijven spoelen.
- P332+P313-Bij huidirritatie: een arts raadplegen.
- P337+P313-Bij aanhoudende oogirritatie: een arts raadplegen.
- P362+P364-Verontreinigde kleding uittrekken en wassen alvorens deze opnieuw te gebruiken.
- P501b-Inhoud/verpakking afvoeren naar verwerken volgens de plaatselijke/regionale/nationale/internationale voorschriften.
Aanvullende informatie
- MIXTURE LIST-Bevat: Guanidine hydrochloride, acetic acid, sodium lauryl sulphate, sodium hydroxide
Your input is important to us. Please complete this form to provide feedback related to the content on this product.
For Research Use Only. Not for use in diagnostic procedures.