Lovibond™ MD 100 Single-Parameter Photometer: COD
Provides accurate and reproducible results very quickly. Lovibond MD 100 Photometer uses high quality interference filters with long-life LEDs as a light source without any moving parts in a transparent sample chamber. Other features include ease of operation, ergonomic design, compact dimensions and safe handling.
Merk: Lovibond™ 276120
Inclusief: Instrument in a carrying case, three round glass vials with lids, one stirring rod and brush, 4 x AAA batteries, warranty information, Certificate of compliance, instruction manual
Beschrijving
The calibration and software-based adjustment options mean that the MD 100 is also suitable for use as a testing instrument. The tests are conducted using either Lovibond tablet reagents with long term stability and a guaranteed minimum five or 10 year shelf life, VARIO powder reagents or using liquid reagents.
- Waterproof (as defined in IP68, 1 hour at 0.1m)
- Automatic switch-off
- Real-time clock and date calibration mode
- Backlit LCD display (on keypress)
- Factory calibration and user calibration; Reset to factory calibration possible
- Internal ring memory for 16 data sets
- Infrared interface for test data transfer
Tube Tests
These enable the user to easily perform highly sensitive and precise water testing. When using tube tests measurement is considerably faster and easier, particularly in the case of standard and serial tests. The tube tests contain a precisely measured amount of reagent, thereby avoiding the presence of superfluous chemicals and optimizing test safety. Up to six different measuring ranges are available for the various tests. The tubes are made of special optical glass with a 16mm diameter. They are supplied in a storage and dispatch box together with the digestion or auxiliary reagents. This packaging unit contains 24 or 25 reaction vials and up to two zero vials for photometer system calibration.
Specifications
- Range: 0 to 150mg/L O2, 0 to 1,500mg/L O2, 0 to 15,000mg/L O2
- Light source: LED, interference filter (IF) and photosensor in transparent cell chamber
- Wavelength Accuracy: ±1nm
- Photometric Accuracy: 3% FS (T = 20°C to 25°C)
- Photometric Resolution: 0.01 A
- Temperature: 5° to 40°C
- Relative Humidity: 30 to 90% (non condensing)
- Power Supply: 4 AAA batteries
- Operating Time: approx. 17 hours or 5000 test measurements in continuous mode when display backlight is off
- Dimensions (L x W x H): 15.5 x 7.5 x 3.5cm (6.1 x 3 x 1.5 in.)
- Weight: basic unit approx. 260g
Note
Specifications for each type of tablet as well as a Certificate of Analysis for each lot is available in the download area at www.lovibond.com.
Specificatie
MD 100 Photometer: COD (Test Tube) | |
3% FS | |
Instrument in a carrying case, three round glass vials with lids, one stirring rod and brush, 4 x AAA batteries, warranty information, Certificate of compliance, instruction manual | |
Internal ring memory for 16 data sets | |
0 to 150mg/L O2, 0 to 1,500mg/L O2, 0 to 15,000mg/L O2 | |
260 g |
Backlit LCD | |
3.5 cm | |
15.5 cm | |
LED | |
0.01 A | |
7.5 cm |
Veiligheid en behandeling
- H400-Zeer giftig voor in het water levende organismen.
- H373-Kan schade aan organen.
- H410-Zeer giftig voor in het water levende organismen, met langdurige gevolgen.
Veiligheidsmaatregel
- P303+P361+P353-BIJ CONTACT MET DE HUID (of het haar): verontreinigde kleding onmiddellijk uittrekken. Huid met water afspoelen/afdouchen.
- P305+P351+P338-BIJ CONTACT MET DE OGEN: voorzichtig afspoelen met water gedurende een aantal minuten; contactlenzen verwijderen, indien mogelijk; blijven spoelen.
- P304+P340-NA INADEMING: de persoon in de frisse lucht brengen en ervoor zorgen dat deze gemakkelijk kan ademen.
- P405-Achter slot bewaren.
Aanvullende informatie
- MIXTURE LIST-Bevat: acide sulfurique, sulfate de mercure, su
- REA17-CMR1-Uitsluitend voor gebruik door professionele gebruiker.
Your input is important to us. Please complete this form to provide feedback related to the content on this product.