missing translation for 'onlineSavingsMsg'
Learn More

Thermo Scientific™ Pierce™ magnetische beads voor streptavidine

Purify or immunoprecipitate biotinylated proteins or affinity ligands using streptavidin-coated magnetic particles for magnet-based separation.

Merk:  Thermo Scientific™ 88816

 Bekijk meerdere types van dit product via de

Produktcode. 10150874

  • 412.00 /

om dit product te kopen Registreer vandaag om een webaccount aan te maken

Edge
Explore more special offers
This item is not returnable. View return policy

Beschrijving

Beschrijving

Thermo Scientific Pierce Streptavidin Magnetic Beads accelerate throughput for automated magnetic purification of biotinylated molecules.

Features of Streptavidin Magnetic Beads:

  • High-performance beads—non-aggregating, pre-blocked, iron oxide, superparamagnetic microparticles provide exceptional uniformity for automated HTS and manual applications alike
  • Stable immobilization chemistry—streptavidin is immobilized using leach-resistant chemistry
  • High capacity—superior quality beads with high binding capacity provide rapid and efficient biomolecule purification from complex samples
  • Low non-specific binding—stable, pre-blocked beads provide clean purification products (e.g., antigen eluted in IP with biotinylated antibody) that are compatible with mass spectrometry analysis and other downstream analyses
  • Superior performance—nearly three times higher binding capacity than typical beads from other suppliers, allowing the use of smaller amounts per experiment

Applications:

  • Immunoprecipitate antigens (using biotinylated antibodies) from a wide variety of sources
  • Co-immunoprecipitate interaction complexes using biotinylated antibodies
  • Capture protein-protein interactions in pull-down assays using biotinylated 'bait' proteins
  • Isolate biotin-labeled DNA-protein complexes from cell or tissue extracts
  • Capture single-stranded biotinylated DNA oligos
  • Isolate biotinylated PCR products

These streptavidin magnetic beads are validated and optimized for use with high-throughput magnetic platforms, such as the Thermo Scientific KingFisher 96 and KingFisher Flex Instruments, but the beads also enable premium performance for simple benchtop applications using an appropriate magnetic stand. The iron oxide, super-paramagnetic particles offer superior performance (high capacity and low nonspecific binding) compared with other commercial magnetic beads.

Pierce Streptavidin Magnetic Beads use a recombinant form of streptavidin with a mass of 53kDa and a near-neutral isoelectric point (pI). The protein is a tetramer having four biotin-binding sites. Unlike avidin, streptavidin has no carbohydrate groups, resulting in low nonspecific binding. The high-affinity interaction between streptavidin and biotin cannot be dissociated efficiently except with very harsh conditions, such as boiling in sample loading buffer for SDS-PAGE or 8M guanidine·HCl, pH 1.5. Consequently, it is often possible to elute binding partners in an interaction complex without also eluting the biotinylated component.

TRUSTED_SUSTAINABILITY
Specificatie

Specificatie

1 mL
Upon receipt store at 4°C. Product is shipped on an ice pack.
Liquid
1 ml
Biotin
Streptavidin
Slurry: 10 mg/mL, 1% solids
1 μm
Pierce™
Recombinant
Magnetic Affinity Bead
Product Suggestions

Product Suggestions

Video's
SDS
Documentatie

Documentatie

Certificates
Speciale aanbiedingen

Speciale aanbiedingen

Product Content Correction

Your input is important to us. Please complete this form to provide feedback related to the content on this product.

Product Title

By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.

Thank You! Your feedback has been submitted. Fisher Scientific is always working to improve our content for you. We appreciate your feedback.

For Research Use Only. Not for use in diagnostic procedures.