missing translation for 'onlineSavingsMsg'
Learn More

Thermo Scientific™ Orion™ ROSS™ Sodium Ion Selective Electrodes

Measure sodium ions in aqueous solution quickly, accurately and economically.

Merk:  Thermo Scientific™ 8411BN

477.38 EUR valid until 2025-07-11
Use promo code "25721" to get your promotional price.



 Bekijk meerdere types van dit product via de

Produktcode. 10451213

  • 502.50 /

Please to purchase this item. Need a web account? Register with us today!

Explore more special offers
This item is not returnable. View return policy

Beschrijving

Beschrijving

Measure sodium in aqueous solutions quickly, accurately and economically with Thermo Scientific™ Orion™ Sodium Electrodes. A unique redox internal system with a Thermo Scientific™ Orion™ ROSS™ electrode provides faster response, and greater stability and accuracy than conventional sodium electrodes.

The sodium electrode is commonly used to measure samples such as food, beverages and animal feed.

Features:

  • 8611BNWP is a combination electrode with a Sure-Flow™ junction that allows easy cleaning. When conventional electrode junctions clog, the Sure-Flow junction can be opened and flushed clean simply by pressing the cap. 8411BN is a half cell sensor that requires ROSS reference electrode, Cat. No. 800300 or the ROSS Ultra reference electrode, Cat. No. 800500U to function.

Solutions required:

  • Standards
    • 941706 0.1 M NaCl sodium standard solution, 475 mL bottle
    • 841108 1000 ppm sodium standard solution, 475 mL bottle
    • 941107 100 ppm sodium standard solution, 475 mL bottle
    • 941105 10 ppm sodium standard solution, 475 mL bottle
  • Known standards addition
    • 841109 Sodium known addition standard, 1000 ppm with ISA, 475 mL bottle
    • 650700 Sodium known addition standard, 1 M with ISA, 475 mL bottle
  • ISA
    • 841111 Sodium ISA, 475 mL bottle
  • Electrode fill solution
    • 900010 ROSS sodium and reference electrode filling solution, 5 x 50 mL bottles.
    • For regular sodium measurements (> 10-5 M or 0.2 ppm)
    • 900012 ROSS sodium and reference electrode filling solution, 5 x 50 mL bottles.
    • For low-level sodium measurements (< 10-5M or 0.2 ppm)
    • 841101 Sodium electrode storage solution, 475 mL bottle
  • Recondition solution
    • 841113 Sodium electrode reconditioning solution, 475 mL bottle

Items included with:

  • 841113 Sodium electrode reconditioning solution, 475 mL bottle
  • 841111 Sodium ISA, 475 mL bottle
  • 841109 Sodium known addition standard, 1000 ppm with ISA, 475 mL bottle
  • 841108 1000 ppm sodium standard solution, 475 mL bottle
  • 900010 ROSS sodium and reference electrode. 60mL 1 bottle
  • 841101 Sodium electrode storage solution, 475 mL bottle

Warranty period:

  • 12 months from date of purchase by Buyer or 18 months from date of shipment from Seller, whichever is earlier.
TRUSTED_SUSTAINABILITY
Specificatie

Specificatie

Measures sodium in aqueous solution quickly, accurately, and economically; Unique redox internal system with ROSS™ electrode provides faster response, greater stability and accuracy than conventional sodium electrodes
ROSS half-cell BNC Orion sodium electrode
13 mm
800300 or 800500U
39.3 in.
1 M
Saturated to 10-6 M, saturated to 0.02ppm
ISE Meters
  • 1 x 10-6 M to saturated
  • 0.02 ppm to saturated
No
BNC
0.47 in
900010 for regular Na+ (> 10-5 M or 0.2 ppm)
900012 for low level Na+ (< 10-5 M or 0.2 ppm)
4.72 in
120 mm
Glass Body
32 to 176°F
0°C to 100°C
Sodium Half-Cell Ion Selective Electrode
Product Suggestions

Product Suggestions

Video's
Veiligheid en behandeling

Veiligheid en behandeling

Signaalwoord
  • Waarschuwing

Gevarencategorie
  • AQUATISCH GEVAAR OP LANGE TERMIJN Categorie 3 voor chronische toxiciteit
  • Ernstig oogletsel/oogirritatie Categorie 2
  • AQUATISCH GEVAAR OP LANGE TERMIJN Categorie 3 voor chronische toxiciteit
  • Huidcorrosie/-irritatie Indeling Categorie 2
  • Sensibilisering van de huid Categorie 1
  • Ernstig oogletsel/oogirritatie Categorie 2

Gevarenaanduiding
  • H317-Kan een allergische huidreactie veroorzaken.
  • H315-Veroorzaakt huidirritatie.,Veroorzaakt huidirritatie.
  • H319-Veroorzaakt ernstige oogirritatie.,Veroorzaakt ernstige oogirritatie.
  • H412-Schadelijk voor in het water levende organismen, met langdurige gevolgen.,Schadelijk voor in het water levende organismen, met langdurige gevolgen.
  • H302-Schadelijk bij inslikken.

Veiligheidsmaatregel
  • P264-Na het werken met dit product grondig wassen.
  • P280-Beschermende handschoenen/beschermende kleding/oog­bescherming/gelaatsbescherming dragen.,Beschermende handschoenen/beschermende kleding/oog­bescherming/gelaatsbescherming dragen.
  • P302+P352-BIJ CONTACT MET DE HUID: met veel water/ wassen.
  • P305+P351+P338-BIJ CONTACT MET DE OGEN: voorzichtig afspoelen met water gedurende een aantal minuten; contactlenzen verwijderen, indien mogelijk; blijven spoelen.,BIJ CONTACT MET DE OGEN: voorzichtig afspoelen met water gedurende een aantal minuten; contactlenzen verwijderen, indien mogelijk; blijven spoelen.
  • P332+P313-Bij huidirritatie: een arts raadplegen.
  • P337+P313-Bij aanhoudende oogirritatie: een arts raadplegen.
  • P362-Verontreinigde kleding uittrekken.
  • P403-Op een goed geventileerde plaats bewaren.
  • P501-Inhoud/verpakking afvoeren naar .

SDS
Documentatie

Documentatie

Certificates
Bekijk bijbehorende artikelen
Speciale aanbiedingen

Speciale aanbiedingen

Product Content Correction

Your input is important to us. Please complete this form to provide feedback related to the content on this product.

Product Title

By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.

Thank You! Your feedback has been submitted. Fisher Scientific is always working to improve our content for you. We appreciate your feedback.