Applied Biosystems™ Calibration Install Kit, Fast 96-well

This kit is used to maintain your ViiA™ 7 System with Fast 96-well Block.

Merk:  Applied Biosystems™ 4432557

Produktcode. 11662119

  • 3135.00 / 1 stuk

om dit product te kopen Registreer vandaag om een webaccount aan te maken

Explore more special offers

Inclusief: Background plate; ROI calibration plate; Six spectral calibration plates with FAM™, SYBR™ Green, VIC™, NED™, TAMRA™, and ROX™ dye standards; Two normalization plates; RNase P instrument verification plate
This item is not returnable. View return policy

Beschrijving

Beschrijving

It includes calibration plates to perform a spectral calibration with FAM™, VIC™, ROX™, SYBR™ Green, TAMRA™, NED™ dyes, plates to perform region-of-interest (ROI) calibration, normalization calibration, and to run an RNase P verification. Calibration and verification should be run at least every six months. Please see your instrument maintenance guide for full instructions on use. The dye formulations for your ViiA™ 7 System will improve results with multiplexing by more accurately representing fluorescent spectra found in your real-time PCR experiments.

Calibration and verification should be done at least every six months. Please see instrument maintenance guide for full instructions.

Informatie over bestelling

Store kit at -15° to -25°C

TRUSTED_SUSTAINABILITY
Specificatie

Specificatie

Includes:
• 1 background calibration plate
• 1 ROI calibration plate
• 6 spectral calibration plates with FAM, SYBR Green, VIC, NED, TAMRA, and ROX dye standards
• 2 normalization calibration plates
• 1 RNase P instrument verification plate

Store kit at -5 to -30°C.
Calibration Install Kit
1 kit
QuantStudio™ 12 K Flex, QuantStudio™ 6 Flex, QuantStudio™ 7, ViiA™ 7 System
Real Time PCR (qPCR)
Spectral Calibration
Product Suggestions

Product Suggestions

Video's
SDS
Documentatie

Documentatie

Certificates
Speciale aanbiedingen

Speciale aanbiedingen

Product Content Correction

Your input is important to us. Please complete this form to provide feedback related to the content on this product.

Product Title

By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.

Thank You! Your feedback has been submitted. Fisher Scientific is always working to improve our content for you. We appreciate your feedback.

For Research Use Only. Not for use in diagnostic procedures.