Invitrogen™ Countess™ Cell Counting Chamber Slides and Holder, disposable

Countess Cell Counting Chamber Slides are conveniently packaged for use with the Countess Automated Cell Counter. Each disposable slide features two enclosed chambers. All Countess Cell Counting Chamber Slides (except Cat. No. C10283) are available with vials of trypan blue.

29.65 - 11450.00


Inclusief: Sildes and 20 × 1mL vials of trypan blue (0.4%)

Producten 8
Produktcode Merk Type Aantal Prijs Hoeveelheid en beschikbaarheid  
Produktcode Merk Type Aantal Prijs Hoeveelheid en beschikbaarheid  
10399053
Bekijk documenten
Invitrogen™
C10228
Cell Counting Chamber Slide 50 Slides
141.00
50 stuks
Please to purchase this item. Need a web account? Register with us today!
12098489
Bekijk documenten
Invitrogen™
C10312
Cell Counting Chamber Slide 500 Slides
1370.00
500 stuks
Please to purchase this item. Need a web account? Register with us today!
12157220
Bekijk documenten
Invitrogen™
C10313
Cell Counting Chamber Slide 1250 Slides
3265.00
Please to purchase this item. Need a web account? Register with us today!
12167220
Bekijk documenten
Invitrogen™
C10314
Cell Counting Chamber Slide 2500 Slides
6080.00
2500 stuks
Please to purchase this item. Need a web account? Register with us today!
10665865
Bekijk documenten
Invitrogen™
C10315
Cell Counting Chamber Slide 5000 Slides
11450.00
5000 stuks
Please to purchase this item. Need a web account? Register with us today!
10702404
Bekijk documenten
Invitrogen™
T10282
Trypan Blue Stain 2 x 1 mL
33.31
Please to purchase this item. Need a web account? Register with us today!
15594183
Bekijk documenten
Invitrogen™
AMEP4745
Slide Holder 1 unit
29.65
Please to purchase this item. Need a web account? Register with us today!
11544596
Bekijk documenten
Invitrogen™
C10283
Cell Counting Chamber Slide 50 Slides
139.00
1 stuk
Toevoegen aan winkelmandje
 
Beschrijving

Beschrijving

Countess Cell Counting Chamber Slides are designed exclusively for automated cell counting on the Countess Automated Cell Counter. These individually packaged slides feature two enclosed chambers and are disposable, offering convenience when performing cell culture. The Countess family of automated cell counters employs the widely used trypan blue staining method for cell counting to identify dead cells and measure cellular viability using brightfield.

The disposable Countess Cell Counting Chamber Slides offer convenience in automated cell counting for processing multiple cell samples, busy cell culture facilities, and easy disposal of contaminated or hazardous samples. They also eliminate the risk of contamination from residual samples. After use, Countess slides can be disposed of as standard biohazard waste. Unlike a hemocytometer, there is no need to clean Countess slides before or after use.

Each Countess Cell Counting Chamber Slide has two separate, enclosed chambers for counting one sample in duplicate or two different samples. Cell counting occurs in a central location of the counting chamber. The volume counted is 0.4 μL, the same as counting four 1-mm2 squares in a standard hemocytometer.

The Countess Automated Cell Counter works in three simple steps:

  • Mix 10 μL of sample with 10 μL of trypan blue stain or other desired reagent, including ReadyCount™ stains, and pipet into a disposable Countess chamber slide
  • Insert the slide into the instrument
  • Press 'Count'

That's it—get the total cell count, percent viable cells, and average cell size in as little as 30 seconds.

The Countess Cell Counting Chamber Slides include two vials of trypan blue for brightfield automated cell counting and viability analysis (Cat. Nos. C10228, C10312, C10314, C10313, and C10315). The slides can also be purchased as 1 box of 50 slides without trypan blue (Cat. No. C10283) for use with other stains such as the ReadyCount fluorescent stains. The trypan blue vials are also available for purchase without slides (Cat. No. T10282).

Trypan blue staining is a long-standing and widely used method to measure cellular viability by identifying dead cells. Live cells with intact membranes exclude the dye, while dead cells with compromised membranes become stained, allowing for the differentiation and counting of live and dead cells to assess cellular viability. Trypan blue staining is the method employed by the Countess family of automated cell counters for cell counting, and this 0.4% trypan blue solution is the correct concentration for use on these instruments.

Note: Precipitates are quite common in trypan blue, and typically increase with storage time and freezing. The three approaches below may help minimize trypan blue precipitate in your cell counting samples:

  • Sterile filtration of trypan blue using 0.3-micron filter
  • Centrifugation or passive settling (avoid mixing or vortexing trypan stock solutions)
  • Gentle warming of the 1-mL trypan solution to 37°C for 10 minutes

The Countess Disposable Slide Holder is used to hold the Countess disposable slides. It is designed for use with Countess II FL, Countess 3, and Countess 3 FL automated cell counters and is included with these cell counters. A replacement Countess Disposable Slide Holder (Cat. No. AMEP4745 ) is available for separate purchase. This Countess Disposable Slide Holder is not compatible with the Countess Reusable Slide (Cat. No. A25750).

Video's
Veiligheid en behandeling

Veiligheid en behandeling

Productidentificatie
  • X50 CELL COUNTING CHAMBER SLIDE COUNTESS

Signaalwoord
  • Gevaar

Gevarencategorie
  • Kankerverwekkendheid Categorie 1
  • Giftigheid voor de voortplanting Categorie 2

Gevarenaanduiding
  • H350-Kan kanker veroorzaken.
  • H361-Kan mogelijks de vruchtbaarheid of het ongeboren kind schaden.

Veiligheidsmaatregel
  • P201-Alvorens te gebruiken de speciale aanwijzingen raadplegen.
  • P202-Pas gebruiken nadat u alle veiligheidsvoorschriften gelezen en begrepen heeft.
  • P280-Beschermende handschoenen/beschermende kleding/oog­bescherming/gelaatsbescherming dragen.
  • P308+P313-NA (mogelijke) blootstelling: een arts raadplegen.
  • P501b-Inhoud/verpakking afvoeren naar verwerken volgens de plaatselijke/regionale/nationale/internationale voorschriften.

Aanvullende informatie
  • MIXTURE LIST-Bevat: 2,7-Naphthalenedisulfonic acid

SDS
Documentatie

Documentatie

Product Certifications

For Research Use Only. Not for use in diagnostic procedures.

Product Content Correction

Your input is important to us. Please complete this form to provide feedback related to the content on this product.

Product Title

By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.

Thank You! Your feedback has been submitted. Fisher Scientific is always working to improve our content for you. We appreciate your feedback.