Cytiva HiScreen™ MabSelect™, Xtra™, SuRe™, SuRe LX™ Prepacked Columns
Designed for method optimization and parameter screening for capture of monoclonal antibodies. Cytiva HiScreen™ MabSelect™, Xtra™, SuRe™, SuRe LX™ Prepacked Columns come ready-to-use for convenience.
Merk: Cytiva 28-9269-77
This item is not returnable.
View return policy
Beschrijving
- Ready-to-use columns for convenient process development
- Rigid, highly cross-linked agarose matrix
- Bed height of 10cm is designed to allow method optimization and parameter screening
- Easily connected in series to achieve 20cm bed height
- Small bed volume (4.7mL) gives fast result and minimal sample/buffer consumption
- Reproducible results, scalable to BioProcess columns packed with the same chromatography media using the same linear fluid velocity
MabSelect
- For capture of MAbs from large sample volumes
- Prepacked with protein A-derived media
- Compatible with high flow rates and high pressure when scaling up
- Increased binding capacity enables purification of MAbs from high-level expression feedstock
- Also optimized for Fc-fusion proteins
- Very low, unspecific binding due to high ligand selectivity and matrix hydrophilicity
- Prepacked with protein A-derived media
- With novel, alkali-tolerant recombinant protein A ligand that provides greater stability and allows use of 0.1 to 0.5M sodium hydroxide for cleaning-in-place (CIP)
- Enhanced protease resistance resulting in lower ligand leakage
- High dynamic binding capacity

Specificatie
8 M ureum, 6 M guanidinehydrochloride, 2% benzylalcohol of 20% ethanol | |
Stoppen bij inlaat en uitlaat | |
Filter | |
≈30mg Human IgG | |
HiScreen MabSelect SuRe Prepacked Column | |
10cm | |
Alkali-stabilized Protein A-derived (E. coli) | |
Polypropylene | |
3 bar | |
2° to 8°C |
HiScreen MabSelect SuRe Prepacked Column | |
1 x 4.7mL | |
0.3 inch | |
0.77 cm | |
3.93 in. | |
Ontworpen voor optimalisatie van methoden en het screenen van parameters voor de vangst van monoklonale antilichamen | |
Epoxy Activation | |
85 μm | |
3 to 12 | |
Column |
Veiligheid en behandeling
Productidentificatie
Signaalwoord
Gevarencategorie
Gevarenaanduiding
Veiligheidsmaatregel
Aanvullende informatie
- hiscreen mabselect sure
Signaalwoord
- Waarschuwing
Gevarencategorie
- Ontvlambare vloeistof Categorie 3
Gevarenaanduiding
- H226-Ontvlambare vloeistof en damp.
Veiligheidsmaatregel
- P241-Explosieveilige elektrische/ventilatie-/verlichtings-/ apparatuur gebruiken.
- P280-Beschermende handschoenen/beschermende kleding/oogbescherming/gelaatsbescherming dragen.
- P303+P361+P353-BIJ CONTACT MET DE HUID (of het haar): verontreinigde kleding onmiddellijk uittrekken. Huid met water afspoelen/afdouchen.
- P501b-Inhoud/verpakking afvoeren naar verwerken volgens de plaatselijke/regionale/nationale/internationale voorschriften.
Aanvullende informatie
- MIXTURE LIST-Bevat: ethanol
- UNKNOWN ACUTE-Het mengsel bestaat voor 16.5 procent uit een of meer bestanddelen waarvan de acute toxiciteit niet bekend is.
Product Content Correction
Your input is important to us. Please complete this form to provide feedback related to the content on this product.
Product Title
Spot an opportunity for improvement?Share a Content Correction