Learn More
Cobalt(II) chloride, anhydrous, 97%, Thermo Scientific Chemicals
33.67 - 220.10
Chemische identificatiekenmerken
CAS | 7646-79-9 |
---|---|
Moleculaire formule | Cl2Co |
Molecular Weight (g/mol) | 129.83 |
MDL-nummer | MFCD00010938 |
InChI Key | GVPFVAHMJGGAJG-UHFFFAOYSA-L |
Synoniem | cobalt ii chloride, cobaltchloride, cobalt chloride 0.1 m solution, cobalt ii chloride, anhydrous, cobalt ii-chloride, curator_000013, cobalt chloride anhydrous, wln: co g2, cobalt-ii-chloride |
IUPAC Name | λ²-cobalt(2+) dichloride |
SMILES | [Cl-].[Cl-].[Co++] |
Produktcode | Merk | Aantal | Prijs | Hoeveelheid en beschikbaarheid | |||||
---|---|---|---|---|---|---|---|---|---|
Produktcode | Merk | Aantal | Prijs | Hoeveelheid en beschikbaarheid | |||||
11439517
|
Thermo Scientific Alfa Aesar
B22031.14 |
25 g |
33.67
25 gram |
Log in om dit product te kopen Registreer vandaag om een webaccount aan te maken | |||||
11449517
|
Thermo Scientific Alfa Aesar
B22031.22 |
100 g |
71.74
100 gram |
Log in om dit product te kopen Registreer vandaag om een webaccount aan te maken | |||||
11459517
|
Thermo Scientific Alfa Aesar
B22031.36 |
500 g |
220.10
|
Log in om dit product te kopen Registreer vandaag om een webaccount aan te maken | |||||
Beschrijving
Cobalt(II) chloride is used in humidity indicator in weather instruments. In the anhydrous form, it finds use in electroplating of cobalt, in organic chemistry and is a precursor to cobaltocene, (bis(cyclopentadienyl)cobalt(II), which is a good reducing agent. It also serves as a Lewis acid. Cobalt chloride is an indicator for water in desiccants, owing to the reversible hydration/dehydration coupled with distinct color change. Cobalt chloride is useful for producing invisible ink as it turns blue when heated and becomes invisible once it gets cooled. Cobalt(II) chloride catalyzes cross coupling of aryl halides or vinyl halides with aryl grignard reagents in excellent yields.
This Thermo Scientific Chemicals brand product was originally part of the Alfa Aesar product portfolio. Some documentation and label information may refer to the legacy brand. The original Alfa Aesar product / item code or SKU reference has not changed as a part of the brand transition to Thermo Scientific Chemicals.
ApplicationsCobalt(II) chloride is used in humidity indicator in weather instruments. In the anhydrous form, it finds use in electroplating of cobalt, in organic chemistry and is a precursor to cobaltocene, (bis(cyclopentadienyl)cobalt(II), which is a good reducing agent. It also serves as a Lewis acid. Cobalt chloride is an indicator for water in desiccants, owing to the reversible hydration/dehydration coupled with distinct color change. Cobalt chloride is useful for producing invisible ink as it turns blue when heated and becomes invisible once it gets cooled. Cobalt(II) chloride catalyzes cross coupling of aryl halides or vinyl halides with aryl grignard reagents in excellent yields.
Solubility
Freely soluble in water and methanol. Soluble in alcohol, acetone, ether, glycerol, and pyridine.
Notes
Hygroscopic. Incompatible with strong oxidizing agents.
Chemische identificatiekenmerken
7646-79-9 | |
129.83 | |
GVPFVAHMJGGAJG-UHFFFAOYSA-L | |
λ²-cobalt(2+) dichloride |
Cl2Co | |
MFCD00010938 | |
cobalt ii chloride, cobaltchloride, cobalt chloride 0.1 m solution, cobalt ii chloride, anhydrous, cobalt ii-chloride, curator_000013, cobalt chloride anhydrous, wln: co g2, cobalt-ii-chloride | |
[Cl-].[Cl-].[Co++] |
Specificatie
1049°C | |
735°C | |
7646-79-9 | |
CoCl2 | |
UN3077 | |
cobalt ii chloride, cobaltchloride, cobalt chloride 0.1 m solution, cobalt ii chloride, anhydrous, cobalt ii-chloride, curator_000013, cobalt chloride anhydrous, wln: co g2, cobalt-ii-chloride | |
GVPFVAHMJGGAJG-UHFFFAOYSA-L | |
λ²-cobalt(2+) dichloride | |
129.84 | |
Odorless | |
3.367 |
Cobalt(II) chloride | |
anhydrous | |
Cl2Co | |
MFCD00010938 | |
14,2437 | |
Freely soluble in water and methanol. Soluble in alcohol,acetone,ether,glycerol,and pyridine. | |
[Cl-].[Cl-].[Co++] | |
129.83 | |
97% | |
Hygroscopic |
Veiligheid en behandeling
GHS H Statement
H334-H350-H360-H341-H302-H317
May cause allergy or asthma symptoms or breathing difficulties if inhaled.
May cause cancer.
May damage fertility or the unborn child.
Suspected of causing genetic defects.
Harmful if swallowed.
May cause an allergic skin reaction.
P201-P202-P260-P264b-P270-P271-P272-P280g-P281-P285-P301+P312-P302+P352-P304+P340-P305+P351+P338-P308+P313-P310-P330-P333+P313-P342+P311-P363-P501c
H302+H332-H317-H318-H334-H335-H341-H350i-H360F-H373
missing translation for 'dotInformation' : Transport Hazard Class: 9; Packing Group: III; Proper Shipping Name: ENVIRONMENTALLY HAZARDOUS SUBSTANCES, SOLID, N.O.S.
missing translation for 'einecsNumber' : 231-589-4
missing translation for 'rtecsNumber' : GF9800000
missing translation for 'tsca' : Yes
Recommended Storage : Ambient temperatures
- Product Description: Cobalt(II) chloride, anhydrous
Signaalwoord
- Gevaar
Gevarencategorie
- Acute toxiciteit Categorie 4
- AQUATISCH GEVAAR OP LANGE TERMIJN Categorie 1 voor chronische toxiciteit
- ACUUT AQUATISCH GEVAAR Categorie 1 voor acute toxiciteit
- Kankerverwekkendheid Categorie 1B
- Ernstig oogletsel/oogirritatie Categorie 1
- Mutageniteit van geslachtscellen Categorie 2
- Giftigheid voor de voortplanting BCategorie 1A
- Sensibilisatie van de luchtwegen Categorie 1
- Sensibilisering van de huid Categorie 1
Gevarenaanduiding
- H302-Schadelijk bij inslikken.
- H317-Kan een allergische huidreactie veroorzaken.
- H318-Veroorzaakt ernstig oogletsel.
- H332-Schadelijk bij inademing.
- H334-Kan bij inademing allergie- of astmasymptomen of ademhalingsmoeilijkheden veroorzaken.
- H341-Verdacht van het veroorzaken van genetische schade.
- H350i-Kan kanker veroorzaken bij inademing.
- H360F-Kan de vruchtbaarheid schaden.
- H400-Zeer giftig voor in het water levende organismen.
- H410-Zeer giftig voor in het water levende organismen, met langdurige gevolgen.
Veiligheidsmaatregel
- P280-Beschermende handschoenen/beschermende kleding/oogbescherming/gelaatsbescherming dragen.
- P302+P352-BIJ CONTACT MET DE HUID: met veel water/ wassen.
- P304+P340-NA INADEMING: de persoon in de frisse lucht brengen en ervoor zorgen dat deze gemakkelijk kan ademen.
- P305+P351+P338-BIJ CONTACT MET DE OGEN: voorzichtig afspoelen met water gedurende een aantal minuten; contactlenzen verwijderen, indien mogelijk; blijven spoelen.
- P310-Onmiddellijk een ANTIGIFCENTRUM/arts/ raadplegen.
Aanvullende informatie
- MIXTURE LIST-Bevat: Cobalt chloride (CoCl2)
RUO – Research Use Only
Your input is important to us. Please complete this form to provide feedback related to the content on this product.